Had Tom come out to service our AC unit today. He took the time to explain everything to my wife and I, was on time and very thro, respectful, knowledgeable and a great tech. Being in the service industry myself I know the difference between good and bad service. Moreheart AC and heating is the best out there and I will definitely recommend then to everybody I know. Thank you Tom and everybody at Moreheart.





Brian S.
In Glendale, near West Kings Avenue and North 61st Drive performing Fall preventative maintenance on a Goettl package heat pump. Control board is getting stuck in defrost. Board is bad and system is no longer manufactured; cannot get a new control board for a Goettl system. Recommend replacing 5 ton package system. Checked water heater; water heater elements are good but water sample is very dirty; recommend doing a water heater flush or replacing.


Brian S.
In Glendale, near West Robb Lane and North 58th Avenue performing Fall preventative maintenance on 2 Amana furnaces. At units, checked gas line and flue piping. Removed and cleaned flame sensor and reinstalled. Cycled heat on. Checked back pressure safety switch. Checked limit switched and safeties. Checked volt and amp draws. Changed return air filter and checked splits. Both systems are new and running properly at this time.


Brian S.
In Glendale, near West Carol Ann Way and North 57th Avenue performing a Fall combo preventative maintenance service on an Aerocool evaporative cooler and a Rheem package heat pump. Evap Cooler: Cleaned wet section and drained. Unplugged pumps and motor. Removed motor belt and installed winterization cover on cooler. Package Unit: Cycled system on into cooling and heating mode. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Changed return air filter as customer is tired of the whistle from the return grill; recommend a new 30X20 Bar Face Grill.


Tom G.
In Glendale, near West Dailey Street and North 55th Avenue performing a diagnostic. Upon arrival, found that AC and Evap cooler were running at the same time. Shut off cooler and cycled system. Took temperature splits in each portion of the house. Supply went from 75 to 61. Everything working properly upon departure.


Brian S.
In Glendale, near West Glendale Avneue and North 66th Avenue performing Fall preventative maintenance on an Amana split system. Checked gas line and flue piping; both sealed and proper. Removed and cleaned the flame sensor and re-installed. Cycled system on into heating mode. Checked burners and ignitor; both working. Checked back pressure safety switch, safety shut down; working properly. Checked volt and amp draws. Changed return air filter and checked splits. System is working within manufacturer specifications.


Leonardo G.
In Glendale, near West Escuda Drive and North 76th Avenue performing Fall preventative maintenance on an Amana heat pump. Upon arrival, cycled unit into heating mode. Took temperature reading from supply and return. Washed and dried Air Care filter. At condenser, cleaned and tightened electrical connections. Took volt and amp draws from components. Checked Freon levels with super heat and subcool. Tested start and run capacitor. Washed and rinsed outdoor coil. Unable to access attic at time of service due to spouse sleeping in room. Upon departure, unit is working properly and within manufacturer specifications.


Leonardo G.
In Glendale, near West Taro Lane and North 79th Avenue performing Fall preventative maintenance on an Amana furnace. Upon arrival, cycled unit into heating mode. Replaced intake filter and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked all safety switches and inspected gas supply/line and flue piping. Vacuumed and wiped down cabinet. Upon departure, unit is working properly and within manufacturer specifications.


Leonardo G.
In Glendale, near West Aster Drive and North 47th Drive performing Fall preventative maintenance on an Amana package heat pump. Cycled unit on into heating mode. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Changed return air filter and checked splits. Recommend adding a hard start kit and surge protector for optimal compressor performance.


Tom G.
In Glendale, near Grand Avenue and 53rd Avenue performing a diagnostic on a commercial unit. Fan relay switch is getting stuck and cutting 24v to compressor contactor. Cleaned switch and area. Tested system. Belt is new; amp draws are all within factory ratings.


Leonardo G.
In Glendale, near West Cactus Road and North 53rd Avenue performing routine seasonal preventative maintenance on an Amana package heat pump. Upon arrival, cycled unit into heating mode. Replaced intake filters and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked Freon levels with super heat and subcool. Washed and rinsed outdoor coils. Upon departure, unit is working properly and within manufacturer specifications.


Leonardo G.
In Glendale, near West Quail Avenue and North 63rd Drive performing routine seasonal preventative maintenance on an Amana heat pump. Upon arrival, cycled unit into heating mode. Replaced intake filter. Took temperature readings from supply and return. At condenser, tightened electrical connections. Took volts and amp draws from components. Checked start and run capacitors. Checked Freon levels with super heat and subcool. Washed and rinsed outdoor coils. In attic, checked air handler, duct work, drain line and drain pan. Recommend adding surge protector to protect system form surge; also recommend doing dryer vent/duct cleaning.


Tom G.
In Glendale, near West Frier Drive and Hayward Avenue performing seasonal preventative maintenance on 1 unit. Completed service in accordance with maintenance checklist. System is older but in working order. Would recommend monitoring and budgeting for future replacement.


Brian S.
In Glendale, AZ: DIAGNOSTIC- On arrival, found cooler #15 leaking water on the roof. Unhooked drain line and found line clogged up after the Ptrap. Blew out drain line with 2 CO2 cartridges and resealed drain line. Checked belt on indoor blower and all is looking good. Service complete.


Tom G.
In Glendale, AZ: DIAGNOSTIC- Found primary drain on unit not cut out from factory. Spoke with gm about issue. Cut out drain. Plumbed new line. Sealed secondary pan with silicone as well as evaporative coil box. Vacuumed out water and cleaned out system. Tested lines multiple times; unit is draining properly. Service complete.


Tom G.
In Glendale, AZ: DIAGNOSTIC- Morehart AC to install and furnish 3 ton 14 seer package heat pump system. To include new treated wood for stand, 16X25 bar faced return grill, disconnect, whip kit, thermostat, and drain line. Customer has the option to have evap cooler removed or kept with installation. To hook up to existing low volt, high volt, and ducting. Service complete.


Tom G.
In Glendale, AZ: DIAGNOSTIC- Upon arrival found units #5 and #6 off for conference room. Found y terminal on unit #6 intermittently dropping voltage. Cleaned wiring, checked charge and unit is working properly. Unit #5; compressor has failed. Estimate given to replace unit #5.


Tom G.
In Glendale, AZ: ESTIMATE- Morehart AC to install and furnish 5 ton package heat pump on roof. To include new thermostat, stand 5/12, elbow 21.5/43.5x2.75, drain, disconnect, and fitting for 1/2 conduit to 3/4 with whip. To hook up to existing ducting, low volt, and high volt. Customer wants to add more insulation and address hot spot in main living room. Recommend putting in a high flow 20x25 return in hallway and adding 14 inch return to living room with a 20x20 grill. In addition return and supply ducting will be replaced with 20 inch flex with a 20-14 T. Estimate complete.


Tom G.
In Glendale, AZ: INSTALL PARTS- Thermostat replacement. Service complete.

Tom G.
In Glendale, AZ: PREVENTATIVE MAINTENANCE- Completed maintenance service in accordance with maintenance checklist. At time of service, customer wanted to address airflow issues with front office. Recommend window treatments as well as modifications of current duct system. In addition, they are having an issue with the Ecobee not responding to commands and resetting. During service, I initially had this same issue. The thermostat is not responding to touch controls; would recommend replacing thermostat. Service and estimates for repair complete.


Leonardo G.
In Glendale, AZ: DIAGNOSTIC- Upon arrival, cycled unit into cooling mode. Heard compressor trying to start and function. At the unit, tested capacitor and noticed it running below manufacturer specifications. Replaced under parts and labor warranty. No diagnosis fee due to 5 year membership plan. Upon departure, unit is working properly and within manufacturer specifications.

Brian S.
In Glendale, AZ: DIAGNOSTIC- UPON ARRIVAL, FOUND COMPRESSOR NOT KICKING ON. UPON FURTHER INSPECTION FOUND 55/440 CAPACITOR BAD AND JUMPER TO CONTACTOR BURNT. INSTALLED NEW 55/440 CAPACITOR AND NEW JUMPER. CYCLED ON ALL RUNNING PROPER. SERVICE COMPLETE.

Tom G.
In Glendale, AZ: DIAGNOSTIC- Upon arrival, found unit low on charge causing low pressure switch to shut compressor off. Performed leak search and found indoor coil rusted through. In addition, blower motor is heavily restricted. The electrical terminals are burnt to motor causing it to cycle intermittently. Spoke with homeowner and due to cost of repairs system needs to be replaced.


Leonardo G.
In Glendale, AZ: DIAGNOSTIC- Upon arrival, cycled unit into cooling mode. Found no power to thermostat. At the air handler, found 5 amp fuse blown. Noticed whole control board was shorted out. Control board needs to be replaced to further diagnose the system. Control boards to be picked up from US Air Conditioning.

Leonardo G.
In Glendale, AZ: PREVENTATIVE MAINTENANCE- Upon arrival, cycled unit into cooling mode. Replaced intake filter and took temperature readings from supply and return. At units, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked Freon levels with super heat and subcool. Upon departure, unit is working properly and within factory specifications.


Brian S.

Tom G.
In Glendale, AZ: Installed motor. Breaker kept tripping when applying power. High volt has continuity to ground. Electrician needs to fix electrical.

Brian S.
In Glendale, AZ: Found contactor not engaging; installed new, 2 pole, contactor. Cycled system back on; Freon levels are good, as well as amp draws. System is working properly and within manufacturer specifications. Hood vent exhaust fan motor is over amping; needs new 1/2 horse 1725 RPM 115 Volt motor. Estimate given to commercial customer.