Evap cooler repair
Sally - Avondale, AZ
I have an almost-new evap cooler that was installed by Morehart and is under warranty. It started blowing hot air, and I assumed that the water pump had quit (sometimes these basic pumps don't last). I was extremely pleased that Morehart scheduled a repair immediately! Brian arrived quickly and replaced the original pump with a heavier duty model.





Leonardo G.
In Avondale, AZ: DIAGNOSTIC- Upon arrival, cycled unit into cooling mode. Found unit cycling on and off very constant. Found power to Y terminal voltage cutting in and out. Replaced nest thermostat. Upon departure, unit is working properly and within manufacturer specifications. Service complete.


Leonardo G.
In Avondale, AZ: DIAGNOSTIC- Upon arrival, cycled unit into cooling mode. Exactly a year ago, TXV was replaced. Found unit an ounce low; recharged system. Upon departure, unit is working properly and within manufacturer specifications. Service complete.


Brian S.
In Avondale, AZ: ON ARRIVAL FOUND COMPRESSOR NOT RUNNING. UPON FURTHER INSPECTION FOUND 45/5/440 RUN CAPACITOR BAD 0.0/0.0/440; WARRANTIED OUT RUN CAPACITOR PART; WARRANTY ONLY.

Leonardo G.
In Avondale, AZ: Upon arrival, cycled unit into cooling mode. Left homeowner with intake filters and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked Freon levels with super heat and subcool. Washed and rinsed outdoor coils. Upon departure, unit is working properly and within manufacturer specifications.


Brian S.
In Avondale, AZ: Cycled system on in cooling, checked volt and amp draws, all within factory specs. Cleaned and tightened electrical connections. Checked Freon levels and pressures, also in factory specification. Acid washed outdoor coil and rinsed. Changed return air filter and checked splits, return 74 supply 54. System is running properly at this time.


Tom G.
In Avondale, AZ: Upon arrival, found unit running when nest was off. There is power coming from nest while in off position. Tested circuit board and wiring. Nest is not sending enough voltage to turn system on and when it does the power gets stuck on. Customer purchased nest and will warranty it out.

Brian S.
In Avondale, AZ: CYCLED SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 74 SUPPLY 54. SYSTEM IS RUNNING PROPER AT THIS TIME.


Brian S.
In Avondale, AZ: CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTERS AND CHECKED SPLITS, RETURN 74 SUPPLY 54. SYSTEM IS RUNNING PROPER AT THIS TIME. CYCLED UP STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTERS AND CHECKED SPLITS, RETURN 76 SUPPLY 55. SYSTEM IS RUNNING PROPER AT THIS TIME.

Brian S.
In Avondale, AZ: CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS FOUND 7.5/440 RUN CAPACITOR OUT OF SPECIFICATION, NEEDS NEW 7.5/440 RUN CAPACITOR. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALL IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 76 SUPPLY 57. CYCLED UP STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL RUNNING PROPER AT THIS TIME. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALL IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 75 SUPPLY 56. SYSTEM IS RUNNING PROPER AT THIS TIME. SECONDARY DRAIN PAN IS HIGHLY RUSTED. CUSTOMER HAS HOME WARRANTY.

Tom G.
In Avondale, AZ: Completed quality inspection on new system install.

Tom G.
In Avondale, AZ: Upon arrival, cycled 1 unit into cooling mode. Replaced intake filters and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked Freon levels with super heat and sub cool. Checked start and run capacitors. Upon departure, unit was working properly and within manufacture specifications.

Tom G.
In Avondale, AZ: Upon arrival found distribution line broke in half. Spider line assembly will need to be replaced. In addition pump is seized. There is very heavy build up on pads. Customer is undecided if she wants to replace herself or not. Float is operational. Completed service but unit needs repairs listed in estimate to make it functional. Cooler is in very poor condition for being less than a year old. Recommended having some filtration installed on home as well as adding a clean machine to system. Pending approval.

Brian S.
In Avondale, servicing a newly installed Amana. Cycled the heat for the first time, volt and amp draws good. Checked Freon levels. Tightened electrical connections forced defrost on the unit all working proper. Changed the customers filter and washed the outdoor coil.


John S.
Just installed a new swamp cooler in the Friendship park neighborhood in Avondale. Customer was excited to finally be cooled off!